If interior ambient heat range sensor malfunction takes place in fan mode, just the mistake code is usually displayed and the indoor unit will operate normally.If the PCB can be to become replaced, please get off the aged for the fresh PCB.
Karda Dehumidifier Code Is Usually![]() Please examine it by mentioning to the resistance desk for temperature sensor). Compressor will work while indoor enthusiast will cease operation. In normal state, the resistance for this terminal should be much less than 1 ohm. The device should not be used by kids without supervision. ![]() If outside unit picks up the higher pressure switch iscut off fór 3-sec successively, higher pressure protection will happen.All the loads (except the 4-way valve in heating system mode) will be turned off. In thiscase, all the control keys and remote control control indicators except ONOFF key will become disabled and system wont be recovered automatically. Switch off the device or re-energize the unit after slicing off energy to eliminate this safety. If interior unit detects the evaporator temperatures is usually lower than protecting temperate value after the unit has happen to be operating for a time period of time undercooling or dry mode, the unit will survey this fault, in which situation the compressor and outdoor fan motor will end up being stopped. The device will not really run until evaporator temperature is increased than the protecting temp. If the safety occurs more than 6 occasions, the unitcannot be recovered automatically. Switch off the unit or re-energize the unit aftercutting off strength to reset to zero this safety. If the outside unit does not get information from interior unit, conversation breakdown will end up being reported. If there can be communication abnormality between screen board and in house unit,communication breakdown will become reported. If the inside unit does not obtain transmission from interior fan engine for 30-secsuccessively when the enthusiast motor can be operating, indoor fan electric motor failure will end up being reported. In thiscase, the unitcan instantly resume procedure after stopping. If the failure takes place 6 occasions within one hour, the unitcannot be recovered immediately. Change off the device or re-energize the unit after slicing off strength to remove this malfunction. If inside unit picks up the condensate overflow change warning for 8-secsuccessively, the system will entercondensate overflow protection.The device will shut off and will not really recover immediately. Switch unit off and then change it on to remove this failure. If in house unit picks up the indoor ambient temperatures sensor is certainly open routine or shortcircuit fór 5-secsuccessively, indoor ambient temp. If in house ambient temperatures sensor malfunction happens in enthusiast mode, just the error code will be shown and the inside device will work normally.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |